MIXED GAS · PRODUCT DETAIL

Environmental Monitoring Standard Gas

Environmental monitoring gas mixtures for calibration and monitoring applications, supplied in 1–8 L cylinders with a standard filling pressure of 9.5 MPa.

Home Products Mixed Gas Environmental Monitoring Standard Gas
ENV MONITORING GAS
Environmental Monitoring Standard Gas
ENVIRONMENTAL MONITORING GAS MIXTURE

Environmental Monitoring Standard Gas

环保监测混合气体

The catalog lists Environmental Monitoring Gas Mixture with multiple standard gas components and concentration ranges for environmental monitoring applications. Product specification is 1–8 L cylinders with a standard filling pressure of 9.5 MPa.

Catalog Name Environmental Monitoring Gas Mixture
Cylinder Volume 1–8 L
Standard Filling Pressure 9.5 MPa
Configuration Customizable

Environmental Monitoring Gas Mixtures

The catalog lists Environmental Monitoring Gas Mixture as a mixed-gas product for environmental monitoring and related analytical applications.

Available listed components include SO₂, NO, H₂S, NH₃, CO, CO₂, Cl₂ and NO₂, plus a TVOC formulation for indoor air quality measurement.

Product specification is 1–8 L cylinders with a standard filling pressure of 9.5 MPa. Composition and concentration range can be configured according to requirements.

Catalog Name Environmental Monitoring Gas Mixture
Chinese Name 环保监测混合气体
Product Category Mixed Gas
Standard Filling Pressure 9.5 MPa
Package 1–8 L Cylinders
Custom Configuration Available
Product Name Environmental Monitoring Standard Gas
Catalog Name Environmental Monitoring Gas Mixture
Chinese Name 环保监测混合气体
Cylinder Volume 1–8 L
Standard Filling Pressure 9.5 MPa
Custom Configuration Composition and concentration range can be configured according to requirements.

Listed Components & Concentration Ranges

Component Concentration Range Balance Gas
SO₂ 2 ppm–1% N₂
NO 5–5000 ppm N₂
H₂S 5 ppm–1% N₂
NH₃ 5 ppm–1% N₂
CO 0.5 ppm–1% N₂ / Air
CO₂ 0.5 ppm–16% N₂ / Air
Cl₂ 1–1000 ppm N₂
NO₂ 1–1000 ppm N₂ / Air
TVOC Benzene, toluene, ethylbenzene, p-xylene, m-xylene, o-xylene and styrene: 200 mg/m³ each N₂

TVOC is listed in the catalog for indoor air quality measurement. The listed components are benzene, toluene, ethylbenzene, p-xylene, m-xylene, o-xylene and styrene, each at 200 mg/m³, with N₂ as the balance gas.

Catalog Handling Note: Standard gases containing SO₂, H₂S, NO, NO₂ and NH₃ are stored in specially treated cylinders. For concentrations above 5000 ppm, a stainless-steel cylinder valve is required.

Environmental Monitoring Standard Gas can be configured according to the required component, concentration range and balance gas options listed in the catalog.

01

Component

Select SO₂, NO, H₂S, NH₃, CO, CO₂, Cl₂, NO₂ or TVOC according to the monitoring requirement.

02

Concentration

Select the required concentration within the listed range for the component.

03

Balance Gas

Available listed balance gases include N₂ and Air depending on component.

04

Cylinder

Product specification: 1–8 L cylinders, standard filling pressure 9.5 MPa.

STEP 01 Select Component
STEP 02 Define Concentration
STEP 03 Confirm Balance Gas
STEP 04 Submit Inquiry
REQUEST A CONFIGURATION

Need Environmental Monitoring Standard Gas?

Tell us your required component, concentration, balance gas, cylinder volume and other requirements.

Scroll to Top